Koolance ICM-505 User Manual

Browse online or download User Manual for Hardware Koolance ICM-505. Koolance ICM-505 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954
Other Technology Pending U.S. & World-Wide Patents
Superior Liquid Cooling Systems
®
English v1.00
ICM-505
Users Manual
ICM-505
Users Manual
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - User’s Manual

Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sys

Page 2 - User Manual

5User ManualSystem SettingsBy default, the ICM-505 automatically adjusts fan speeds based on the liquid temperature at the CPU (see CPU Cooler for sen

Page 3

6LED Display - Alarm SettingsBy default, the Koolance audio alarm will sound if the primary sensor reaches 55ºC (131ºF). When the system alarm sounds,

Page 4 - Table of Contents

7User ManualChapter2Installing the ICM-505

Page 5 - Required Tools

8 Installing the ICM-505Mounting the ICM-505The ICM-505 mounts via a rear 120mm fan grill. If you already have a 120mm fan installed in your comput

Page 6 - Chapter1

9User ManualCAUTION: The “Power” connection is vital to system operation. A 12V 4-pin plug from the power supply must remain connected to the cooling

Page 7 - Advantages of Water Cooling

10 Installing the ICM-505Sensor - The Koolance temperature probe is connected here. The sensor end will be taped to the bottom of the CPU Cooler du

Page 8

11User ManualEach tubing connection uses a threaded compression fi tting (“hose screw”) to keep it secure. To connect these components:Connecting Hoses

Page 9 - ICM-505 Overview

12 Installing the ICM-505Hose LengthsBefore installing your liquid coolers, appropriate lengths of tubing must be cut to connect each device. If no

Page 10 - LED Display Panel (Optional)

13User ManualChapter3*Installing the CPU Cooler*NOTE: Images of the CPU Cooler in this chapter may differ from your specifi c model. However, the actua

Page 11

14 Installing the CPU CoolerTemperature SensorRemove the protective fi lm from the bottom of the CPU cooler.Insert the temperature sensor into eithe

Page 12 - Chapter2

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Page 13 - Mounting the ICM-505

15User ManualFor AMD Athlon/XP processors, the left or right receptacles will be used, depending on which direction the CPU socket faces in relation t

Page 14 - Wire Connections

16Screw alignment for P-4, Xeon, Athlon 64, FX, and Opteron processorsWith the bracket properly aligned, insert and slowly twist the tension screw unt

Page 15

17User ManualClips for Intel P-4 socket 478Clips for AMD socket 472 & Intel P-III socket 370Fit the cooler and mounting brackets onto the CPU sock

Page 16 - Connecting Hoses

18 Installing the CPU CoolerAMD Socket 939, 754, & 940 ProcessorsThe AMD 64 Adapter is designed for AMD Athlon 64, FX, and Opteron processors i

Page 17 - Hose Lengths

19User ManualFinally, squeeze the remaining tabs together beneath the board, and gently push them through with long-nose pliers.This should allow you

Page 18 - Chapter3

20 Installing the CPU CoolerPlastic Washer (with Long Screw)Bottom Metal Nut (with Long Screw)Be sure to install the temperature sensor before moun

Page 19 - Temperature Sensor

21User ManualIntel Socket LGA-775 (“T”) ProcessorsThe LGA 775 Adapter is designed for Intel LGA 775 (“Socket T”) processors. The motherboard should be

Page 20 - Tension Screw

22Apply thermal paste to the CPU directly. Spread the paste so that it evenly covers the processor. A piece of thick paper (such as a business card) w

Page 21

23User ManualChapter4Filling & MaintenanceWARNING: KEEP KOOLANCE LIQUID COOLANT AND ALL CHEMI-CALS OUT OF THE REACH OF CHILDREN. KOOLANCE LIQUID C

Page 22 - & Intel P-III socket 370

24Testing & FillingOnce all of the coolers have been connected, the system can be fi lled with coolant. Swing open the ICM-505, and remove the larg

Page 23

iiWARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICAL

Page 24 - Short Metal Screws

25User ManualThe liquid coolant should be fi lled up to about 1.5 cm (1/2”) from the reservoir’s top. This small gap will catch air as it circulates th

Page 25

26The coolant in your system should be emptied for any of the below reasons:1. To Keep it Clean - Koolance recommends replacing the liquid coolant abo

Page 26

27User ManualYour Koolance system is designed to provide you with years of reliable cooling performance if maintained properly. To help avoid unnecess

Page 27

284. After the system has been on for awhile, the temperature alarm sounds...Make sure the LED temperature is at or above your preset alarm temperatur

Page 28 - Chapter4

29User Manual6. My system appears to be leaking fl uid...Since users are allowed to confi gure their own coolers and clamps, it is possible a connection

Page 29 - Testing & Filling

30Limited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defects in mate

Page 30

www.koolance.comISO 9001Printed in Korea

Page 31 - Draining & Maintenance

iiiUser ManualTable of ContentsIntroduction 1ICM-505 Overview ...

Page 32 - Troubleshooting

iv ICM-505 Series Systems: - CPU Cooler - ATX power jumper wire - refi ll funnel - liquid coolant mixture - liquid tubing - user manualIncluded H

Page 33

1User ManualChapter1Introduction

Page 34

2 Congratulations on your purchase of a Koolance system!As the most sophisticated product of its kind, Koolance offers many unique features found now

Page 35 - Disclaimer

3User ManualThe heart of a liquid cooling system is the pump. This device pushes liquid through each cooler and into the heat exchanger. Koolance syst

Page 36 - Printed in Korea

44 IntroductionICM-505 OverviewReservoir & PumpsRadiator Cooling FanReservoir Refi ll PlugRadiator (Primary Heat Exchanger)Power CircuitConnecti

Comments to this Manuals

No comments